Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
Visit old site
Home Print this page Email this page Small font size Default font size Increase font size
Users Online: 926
TECHNICAL ARTICLE
Year : 2011  |  Volume : 3  |  Issue : 8  |  Page : 384-386

Whole blood viscosity extrapolation formula: Note on appropriateness of units


1 Nepean Hospital Pathology; Derby Street Kingswood, NSW 2747, Australia
2 School of Community Health, Charles Sturt University Albury, NSW 2640, Australia

Correspondence Address:
Ezekiel Uba Nwose
Institute of Clinical Pathology & Medical Research, Nepean Hospital Pathology, Derby Street, Kingswood, NSW 2747
Australia
Login to access the Email id

Source of Support: None, Conflict of Interest: None


PMID: 22171247

Rights and PermissionsRights and Permissions

Background : A series has recently been done on whole blood viscosity. The first on the series proposed extrapolation chart with conventional reference range. Since the publication, two concerns have been received in personal communications. The first expressed concern over the use of serum proteins values in 'g/L' instead of 'g/dL' that was contained in the referenced material. The second enquired on suitability of the formula for determination of blood viscosity at low shear rate. Aim : This work sets out to compare different units-converted-modifications of the extrapolation with a view to develop a statement of comparison and suitability of units. Materials and Methods : The values of haematocrit and serum proteins were used in different unit-conversions on the mathematical formula to derive four modifications, which were compared. Five clinical cases that were specifically tested for whole blood viscosity, and had results for haematocrit and serum proteins were evaluated. The appropriateness of modifications for determination of viscosity at low shear rate was reviewed. Results : Except as modified and used in the series, determination of whole blood viscosity at low shear rate using other unit conversions on the formula yields negative values for all five cases. Conclusion : Given that it is unexpected for blood viscosity level to be zero let alone less, it is logical that negative values are invalid. A formula that gives the least invalid results may be most appropriate. Therefore, extrapolation modification used in the series is most appropriate.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed1782    
    Printed117    
    Emailed0    
    PDF Downloaded232    
    Comments [Add]    

Recommend this journal